 General Purpose Industrial Pressure Transducer - Vacuum to 6000 psi (400 bar)

Quick Specs...

  • Millivolt, Voltage and Current Output Models 
  • Gauge, Absolute, Vacuum and Compound Pressure Models Available  
  • Submersible, General Purpose and Wash Down Enclosures 
  • High Stability Achieved by CVD Sensing Element 

 

Overview / Design Principle:

The 2600 series pressure transducer features stability and accuracy in a variety of enclosure options and extends the packaging options via an all welded stainless steel back end for demanding submersible and industrial applications. The 2600 series pressure transducer features proven CVD sensing technology, an ASIC (amplified units), and modular packaging to provide a sensor line that can easily accommodate specials while not sacrificing high performance.

Typical Applications: 

  • Off Highway Vehicles
  • Natural Gas Equipment 
  • Semiconductor Processing 
  • Power Plants 
  • Refrigeration 
  • Robotics 
  • HVAC
Specifications 
  Input   

Pressure Range  

Vacuum to 400 bar (6000 psi) 0-25 bar Absolute 

Proof Pressure  

2 x Full Scale (FS) (1.5 x Fs for 400 bar), >= 5000) 

Burst Pressure  

>35 x FS <= 6 bar (100 psi)
>20 x FS >=60 bar (1000 psi)
>5 x FS <=400 bar (6000 psi)
 

Fatigue Life  

Designed for more than 100 million FS cycles  

Performance 

Long Term Drift  

0.2% FS/year (non-cumulative)  

Accuracy  

0.25% FS typical  (optional 0.15% FS) 

Thermal Error  

1.5% FS typical (optional 1% FS)  

Compensated Temperature  

-20° C to 80° C (-5° F to 180° F)  

Operating Temperatures  

-40° C to 125° C (-22° F to 260° F) for elec. codes C, 1
-20° C to 80° C (-5° F to 180° F) for elec. codes G, 3
-20° C to 50° C (-5° F to 125° F) for elec. codes M
 

 Zero Tolerance  

 1% of span  

Span Tolerance  

 1% of span  

Response Time  

  0.5 ms 

  Mechanical Configuration     

Pressure Port  

See ordering chart  

Wetted Parts  

17-4 PH Stainless Steel  

Electrical Connection  

See ordering chart  

Enclosure  

316 ss, 17-4 PH ss
IP65 for elec. codes C, G, 1, 3
IP68 for elec. code M
IP30 for elec. code "3" with flying leads
 

Vibration  

70g, peak to peak sinusoidal, 5 to 2000 Hz
(Random Vibration: 20 to 2000 Hz @ approx. 20g Peak per MIL-STD. -810E Method 514.4)
 

Acceleration  

100g steady acceleration in any direction 0.032% Fs/g for 1 bar (15 psi) range decreasing logorithmically to 0.0007% for FS/g for 400 bar (6000) psi range 

Shock  

20g, 11 ms, per MIL-STD.-810E
Method 516.4 Procedure 1 
 

Approvals  

CE, UR (22ET, 26ET Intrinsically safe)  

Weight  

Approx. 100 grams (additional; cable 75 g/m)  

   Voltage Output Units      

Output  

See ordering chart 

Supply Voltage (Vs)  

1.5 Vdc above span to 35 Vdc @ 6 mA  

Supply Voltage Sensitivity  

0.01% FS/Volt  

Min. Load Resistance  

(FS output / 2) K ohms  

Current Consumption  

Approx 6 mA at 7.5V output  

  Current Output Units      

Output  

4-20 mA (2 wire)  

Supply Voltage (Vs)  

24 Vdc, (7-35 Vdc)  Above 100° C supply limited to 24 Vdc 

Supply Voltage Sensitivity  

0.01% FS/Volt  

Max. Loop Resistance  

(Vs-7) x 50 ohms  

  Millivolt Units      

Output  

100 mV (10 mv/v) 

Supply Voltage (Vs) 

10 Vdc (15 Vdc max.) Regulated  

Bridge Resistance  

 2600-6000 ohms  