Preset |
2 presets |
Preset setting |
Press reset button and hold. Enter desired value in any order. Release reset button. |
Limit switch |
Trigger at preset 1 (adding) |
Precontact |
Trigger at preset 2 |
Output contact |
Change-over contact |
Switching voltage |
230 VAC / VDC |
Switching current |
2 A |
Switching capacity |
100 VA / 30 W |
Spark extinguisher |
Recommended for inductive load |
Function |
Meter counter with preset |
Display |
White numbers on black
Decimal digits in red |
Number of digits |
5-digits |
Digit height |
7 mm |
Count mode |
Adding in a rotational direction
to be indicated, subtracing in
reverse direction.
See part number key |
Drive shaft |
Both sides, ø7 mm |
Reset |
By reset lever to preset value.
Do not let snap lever or make jerky movements. |
Measuring speed |
2 revs. = 1 digit = <3000 m/min
2 revs. = 10 di. = <300.0 m/min |
Measuring precision |
1 m, 1 dm |
Measuring range |
9 999.9 m and 99 999 m |
Operating temperature |
0...+60 °C |
Housing type |
Surface mount housing |
Housing colour |
Grey |
Dimensions W x H x L |
120 x 105 x 95 mm |
Dimension mounting plate |
158 x 105 mm |
Mounting |
Base plate, 4 mounting holes |
Weight approx. |
1400 g |
Material |
Aluminium die cast alloy |
E-connection |