All Products

 

SENA Parani-UD100
SENA / UD100 / Parani-UD100
From 39,00 €
Trycom Bluetooth to RS 232 RS 422 RS 485 Converter
Trycom / TRP-C51 / Bluetooth to RS 232 RS 422 RS 485 Converter
From 179,20 €
Trycom Ethernet to fiber media converter
Trycom / TRP-C41 / Ethernet to fiber media converter
From 150,88 €
Trycom Fiber to RS 232 RS 422 RS485 Isolated Converter
Trycom / TRP-C39S / Fiber to RS 232 RS 422 RS485 Isolated Converter
From 301,75 €
Trycom Fiber to RS 232 RS 422 RS 485 Isolated Convertor
Trycom / TRP-C39 / Fiber to RS 232 RS 422 RS 485 Isolated Convertor
From 187,90 €
Trycom Ethernet Serial Server
Trycom / TRP-C37M / Ethernet Serial Server
From 310,00 €
Trycom Ethernet to RS-232/422/485 Converter
Trycom / TRP-C37 / Ethernet to RS-232/422/485 Converter
From 116,59 €
Trycom Ethernet converter RS 232 RS 422 RS 485 Isolated
Trycom / TRP-C36 / Ethernet converter RS 232 RS 422 RS 485 Isolated
From 130,30 €
Trycom Converter Ethernet 4 ports RS 232 RS 422 RS 485
Trycom / TRP-C34 / Converter Ethernet 4 ports RS 232 RS 422 RS 485
From 301,75 €
Trycom USB 2.0 to 4 ports RS-232  Isolated Convertor
Trycom / TRP-C08U / USB 2.0 to 4 ports RS-232 Isolated Convertor
From 124,81 €
Trycom USB to 1 port RS 232 and RS 422 RS 485 Isolated
Trycom / TRP-C08S / USB to 1 port RS 232 and RS 422 RS 485 Isolated
From 105,61 €
Trycom  USB 2.0 to 2 ports RS-232 and 2 ports RS-422/485
Trycom / TRP-C08H / USB 2.0 to 2 ports RS-232 and 2 ports RS-422/485
From 171,45 €
Trycom USB to RS 232 RS 422 RS 485 Isolated Converter
Trycom / TRP-C08 / USB to RS 232 RS 422 RS 485 Isolated Converter
From 165,50 €
Trycom RS 422 RS 485 Isolated Repeater
Trycom / TRP-C07 / RS 422 RS 485 Isolated Repeater
From 116,59 €
Trycom Dual port RS 232 to RS 422 RS 485 Isolated
Trycom / TRP-C06H / Dual port RS 232 to RS 422 RS 485 Isolated
From 102,87 €
Trycom RS 232 to RS 422 RS 485 Isolated Converter
Trycom / TRP-C06 / RS 232 to RS 422 RS 485 Isolated Converter
From 69,00 €
Sena Parani-SD1100
Sena / SD1100 / Parani-SD1100
SENA Parani-SD1000
SENA / SD1000 / Parani-SD1000
From 95,00 €
Altii Convertor USB RS232 usb to serial
Altii / RS232C-009 / Convertor USB RS232 usb to serial
From 6,80 €
Sena ZigBee USB Adapter
Sena / ProBee-ZU10 / ZigBee USB Adapter
From 59,00 €
Sena ZigBee USB Adapter
Sena / ProBee-ZS10 / ZigBee USB Adapter
From 59,00 €
Sena ZigBee USB Adapter
Sena / ProBee-ZE10 / ZigBee USB Adapter
From 26,00 €
SENA Parani-SD200
SENA / Parani SD200 / Parani-SD200
From 86,00 €
SENA Parani-MSP1000
SENA / MSP1000 / Parani-MSP1000
From 599,00 €
SENA LTC-100
SENA / LTC100-01 / LTC-100
From 49,00 €
SENA Server Extern pentru Dispozitive
SENA / LS100/100B/110 / Server Extern pentru Dispozitive
From 90,00 €
Korenix 1 port RS232 RS422 RS485 Serial Device Server
Korenix / JetPort-5601 / 1 port RS232 RS422 RS485 Serial Device Server
From 192,00 €
Korenix Industrial 1-port RS-232 Serial Device Server
Korenix / JetPort-5201 / Industrial 1-port RS-232 Serial Device Server
From 173,00 €
N/A USB to 2-port RS-232 Adapter
N/A / FB1220 / USB to 2-port RS-232 Adapter
From 26,60 €
N/A USB to 2-port RS-485 Hub
N/A / FA1320 / USB to 2-port RS-485 Hub
From 30,80 €
SENA Parani-ESD210
SENA / ESD210 / Parani-ESD210
From 55,00 €
SENA Parani-ESD200
SENA / ESD200 / Parani-ESD200
From 55,00 €

Page 1 of 2First   Previous   [1]  2  Next   Last   
Mod de functionare

O pompa va porni automat cand plutitorul nr. 2 (cel din mijloc) schimba starea in peste nivel.
Pompa va merge atat timp cat plutitorul nr. 1 este peste nivel.
Daca plutitorul nr. 3 este activat (peste nivel) atunci si a doua pompa va intra in functiune.
De asemenea, fiecare pompă va avea o protecție termică NC (normal închisă).
Acestia sunt singurii doi parametri care controlează pompa.
Un al treilea parametru va fi curentul utilizat de pompă și va fi citit direct în controlerul PCB printr-un transformator de curent (maxim 10 A).
Dacă apare oricare dintre următoarele situatii, controller-ul va comuta pompa in starea FAULT:
1. Curentul depășește limita pre-stabilită;
2. Protecția termică este deschisă.

Daca pompa a depasit un numar de secunde de functionare presetat (cu toate ca nivelul apei este inca ridicat), atunci programul va porni pompa alternativa. Daca a doua pompa este in AVARIE , atunci programul se va opri.

De asemenea firmware-ul va detecta succesiunea fazelor, cu eroare daca nu este corecta.
Programul porneste ambele pompe doar data plutitorul nr. 3 este peste nivel.