All Products

CEM Digital Sound Noise Level Data Logger

From 110,00 €
This meter has a built-in USB port which connects to a Windows PC for uploading the recorded data. This is an ideal instrument for noise monitoring in factory, school, business and traffic areas.
Stock
-1
Code
DT-173
Quantity
  

CEM Digital Sound Noise Level Data Logger

 DT-173 High Accuracy Digital Sound Noise Level Data Logger Datalogger with USB Interface

This meter has a built-in USB port which connects to a Windows PC for uploading the recorded data. This is an ideal instrument for noise monitoring in factory, school, business and traffic areas. This meter conforms to the IEC61672-1 Class 2 standards. This device operates on a 3.6V Lithium battery. This device is very accurate (+/- 1.4 dB) and durable, an ideal companion for your field projects. 

Please note that the FREE Windows software is provided AS IS.  There is no software development kit nor engineering support for the software.

  Features

  • Conforms to the IEC61672-1 Class 2 for sound level measurement

  • NORM and PEAK mode 
  • Over range indication
  • A & C frequency weighting
  • Fast (125ms) and slow (1s) time weighting
  • Calibration via software
  • Manual and automatic start modes

Specification

 
Accuracy +/- 1.4 dB
Frequency range 31.5 Hz - 8KHz
Dynamic range 50dB
Measuring ranges

Auto: 30 -130 dB

Time weighting Fast: 128 ms   

Slow: 1 sec

Microphone 1/2 inch electret condener microphone
Data memory 129920 samples
Battery life about 240 hours
LED indicator  Green (operating) and Yellow (memory full) LED
OS compatibility Windows 2000, XP or Vista

 

 

Mod de functionare

O pompa va porni automat cand plutitorul nr. 2 (cel din mijloc) schimba starea in peste nivel.
Pompa va merge atat timp cat plutitorul nr. 1 este peste nivel.
Daca plutitorul nr. 3 este activat (peste nivel) atunci si a doua pompa va intra in functiune.
De asemenea, fiecare pompă va avea o protecție termică NC (normal închisă).
Acestia sunt singurii doi parametri care controlează pompa.
Un al treilea parametru va fi curentul utilizat de pompă și va fi citit direct în controlerul PCB printr-un transformator de curent (maxim 10 A).
Dacă apare oricare dintre următoarele situatii, controller-ul va comuta pompa in starea FAULT:
1. Curentul depășește limita pre-stabilită;
2. Protecția termică este deschisă.

Daca pompa a depasit un numar de secunde de functionare presetat (cu toate ca nivelul apei este inca ridicat), atunci programul va porni pompa alternativa. Daca a doua pompa este in AVARIE , atunci programul se va opri.

De asemenea firmware-ul va detecta succesiunea fazelor, cu eroare daca nu este corecta.
Programul porneste ambele pompe doar data plutitorul nr. 3 este peste nivel.