Process Calibrator VICTOR 11+ VICTOR

VICTOR Process Calibrator

From 1 112,00 €
1.Temperature Coefficient: 0.1 times the applicable accuracy,specification per degree C for 5℃ to 18℃ and 28℃to 50℃.
2.The range of the internal temperature compensation sensor is from 0℃to 40℃, Compensation error ≤±0.5℃.
3.The accuracy of the temperature probe: ±0.2℃.
Stock
-1
Code
VICTOR 11+
Quantity
  

VICTOR Process Calibrator

 

                   VICTOR 11+ - Process Calibrator

 

Features; High Accuracy of 0.02% for source, 6 digits display for source.A dual,

Liquid Crystal Display;White LED for backlight

Function Reference Range Resolution Accuracy Remark
Thermocouple R 0℃~1767℃ 1℃ 0~100℃:1.5℃ By using ITS-90 temperature scale;The accuracy does not include the error of internal temperature compensation caused by a sensor;
100~1767℃:1.2℃
S 0℃~1767℃ 1℃ 0~100℃:1.5℃
100~1767℃:1.2℃
B 600℃~1820℃ 1℃ 600~800℃:1.5℃
800~1820℃:1.1℃
E -200.0℃~1000.0℃ 0.1℃ -200.0~-100.0℃:0.6℃
-100.0~600.0℃: 0.5℃
600.0~1000.0℃: 0.4℃
K -200.0℃~1372.0℃ 0.1℃ -200.0~-100.0℃: 0.6℃
-100.0~400.0℃: 0.5℃
400.0~1200.0℃: 0.7℃
1200.0~1372.0℃: 0.9℃
J -200.0℃~1200.0℃ 0.1℃ -200.0~-100.0℃: 0.6℃
-100.0~800.0℃: 0.5℃
800.0~1200.0℃: 0.7℃
T -250.0℃~400.0℃ 0.1℃ -250.0~400.0℃:0.6℃
N -200.0℃~1300.0℃ 0.1℃ -200.0~-100.0℃: 1.0℃
-100.0~900.0℃: 0.7℃
900.0~1300.0℃: 0.8℃
L -200.0℃~900.0℃ 0.1℃ -200.0~0.0℃:0.7℃
0.0~900.0℃:0.5℃
U -200.0℃~600.0℃ 0.1℃ -200.0~0.0℃:0.7℃
0.0~600.0℃: 0.5℃

 

Other feature:

1、Temperature Coefficient: 0.1 times the applicable accuracy,specification per degree

C for 5℃to 18℃and 28℃to 50℃.

2、The range of the internal temperature compensation sensor is

from 0℃to 40℃, Compensation error ≤±0.5℃.

3、The accuracy of the temperature probe: ±0.2℃.

The range of the measured temperature is form -20℃-100℃.

4、Maximum voltage between any output terminal and earth: 30Vp-p

5、Maximum output current: Approximately 25mA.

                

Mod de functionare

O pompa va porni automat cand plutitorul nr. 2 (cel din mijloc) schimba starea in peste nivel.
Pompa va merge atat timp cat plutitorul nr. 1 este peste nivel.
Daca plutitorul nr. 3 este activat (peste nivel) atunci si a doua pompa va intra in functiune.
De asemenea, fiecare pompă va avea o protecție termică NC (normal închisă).
Acestia sunt singurii doi parametri care controlează pompa.
Un al treilea parametru va fi curentul utilizat de pompă și va fi citit direct în controlerul PCB printr-un transformator de curent (maxim 10 A).
Dacă apare oricare dintre următoarele situatii, controller-ul va comuta pompa in starea FAULT:
1. Curentul depășește limita pre-stabilită;
2. Protecția termică este deschisă.

Daca pompa a depasit un numar de secunde de functionare presetat (cu toate ca nivelul apei este inca ridicat), atunci programul va porni pompa alternativa. Daca a doua pompa este in AVARIE , atunci programul se va opri.

De asemenea firmware-ul va detecta succesiunea fazelor, cu eroare daca nu este corecta.
Programul porneste ambele pompe doar data plutitorul nr. 3 este peste nivel.