All Products
Pressure Transducer 1200 Series Gems Sensors

Gems Sensors Pressure Transducer

The 1200 series pressure transducer features stability and toughness via its CVD and ASIC design coupled with a thicker diaphragm. The thicker diaphragm enables these sensors to survive most pressure spikes
Stock
-1
Code
1200 Series

Gems Sensors Pressure Transducer

 OEM Pressure Transducer Featuring Exceptional Proof Pressure and Stability Specifications- Vacuum to 6000 PSI (400 Bar)

Quick Specs... 

  • Voltage and Current Output Models 
  • Gauge, Vacuum, and Compound Pressure Models 
  • General Purpose and Wash Down Enclosures  
  • High Proof Pressure Achieved by Thicker Diaphragm Construction 

Overview / Design Principle: 

The 1200 series pressure transducer features stability and toughness via its CVD and ASIC design coupled with a thicker diaphragm. The thicker diaphragm enables these sensors to survive most pressure spikes caused by pump ripple, solenoid valves, etc. A modular design allows special ordering of fittings, electrical cables, etc. for OEM applications. The ASIC and CVD technology enables Gems to offer almost any output over any pressure range. 

Applications: 

  • Off Highway Vehicles 
  • Natural Gas Equipment 
  • Semiconductor Processing  
  • Power Plants  
  • Refrigeration 
  • Robotics 
  • HVAC
Specifications 

Input 

Pressure Range 

Vacuum to 400 bar (6000 psi) Gauge datum only 

Proof Pressure 

4 x Full Scale (FS) (<1% FS Zero Shift)  

Burst Pressure 

>35 x FS <= 4 bar (60 psi);
>20 x FS <=40 bar (600 psi);
>5 x FS <=400 bar (6000 psi)
 

Fatigue Life 

Designed for more than 100 million FS cycles 

Performance 

Supply Voltage Sensitivity 

0.01% FS/Volt  

Long Term Drift 

0.2% FS/year (non-cumulative)  

Accuracy 

0.5 % FS typical (optional 0.15% FS)  

Thermal Error 

2.0% FS typical  

Compensated Temperatures 

-20°C to 80°C (-5°F to 180°F) 

Operating Temperatures 

-40°C to 125°C (-22°F to 260°F) for elec. codes A, B
-20° to 80°C (-5° to 180°F) for elec. codes 2, D
-20° to 50 °C (-5° to 125°F) for elec. code F temperatures > 100°C supply is limited to 24 Vdc.
 

Zero Tolerance 

1% of span 

Span Tolerance 

1% of span 

Response Time 

0.5 ms 

 Mechanical Configuration 

Pressure Port 

See ordering chart  

Wetted Parts 

17-4 PH Stainless Steel  

Electrical Connection 

See ordering chart  

Enclosure 

316 SS, 17-4 PH ss
IP65 for elec. codes A, B, D, 2
IP67 for elec. codes F
IP30 for elec. code "3" with flying leads
 

Vibration 

70g, peak to peak sinusoidal, 5 to 2000 Hz
(Random Vibration: 20 to 200 Hz @ =20g Peak per MIL-STD.-810E Method 514.4)
 

Acceleration 

100g steady acceleration in any direction 0.032% FS/g for 1 bar (15 psi) range decreasing logarithmically to 0.0007% FS/g for 400 bar (6000 psi) range 

Shock 

20g, 11 ms, per MIL-STD.-810E
Method 516.4 Procedure l 
 

Approvals 

CE, UR (12 ET, 16 ET Intrinsically safe) 

Weight 

Approx. 100 grams (additional; cable 75 g/m) 

 Voltage Output Units 

Output 

See ordering chart  

Supply Voltage (Vs) 

1.5 Vdc above span to 35 Vdc  

Min. Load Resistance 

(FS output / 2) K ohms  

 Current Output Units 

Output 

4-20 mA (2 wire) 

Supply Voltage (Vs) 

24 Vdc, (7-35 Vdc) Above 100°C supply limited to 24 Vdc 

Max. Load Resistance 

(Vs-7) x 50 ohms 

*Electromagnetic Capability 

Meets the requirement for CE marking of EN50081-2 for emissions and EN50082-2 for susceptibility.
Test Data:
• EN61000-4-2 Electrostatic Discharge. 8kV air discharge, 4kV contact discharge. Unit survived.
• ENV50140 Radiated RF Susceptibility. 10V/m, 80MHz-1GHz, 1kHz mod. Maximum recorded output error was <±1%
• ENV50204 Radiated RF Susceptibility to Mobile Telephones. 10V/m, 900MHz. Maximum recorded output error was <±1%.
• EN61000-4-4 Fast Burst Transient. 2kV, 5/50ns, 5kHz for 1 minute. Unit survived.
• ENV50141 Conducted RF Susceptibility. 10Vms, 1kHz mod, 150kHz - 80MHz. Maximum recorded output error was <±1%

Product Documentation

1200 Series
1200 Series - Download PDF
Download