Trafag Switches de Presiune
PRESSOSTAT P...
for low pressure ranges with high accuracy
Data sheet H72252
Instruction H71261
Sensor technology |
bellows |
Sensor material |
bronze |
Protection |
IP65 |
Pressure connection |
G1/4“ female |
Output |
micro switch |
Electrical connection |
terminal screw |
Operating temperature [°C] |
-20...+70 |
Media temperature [°C] |
-40...+150 |
EN 60730-2-6 |
Type 2.B.H. |
Mounting plate see MB31 (chapter Accessories)
Type |
Range P
[bar] |
Max. Overpressure [bar] |
Switching diff. fixed
[bar] |
Diameter Y
[mm] |
Length X
[mm] |
P |
1.5 |
-0.9...1.5 |
10 |
0.1 |
45 |
56.5 |
P |
2.5 |
0.2....2.5 |
10 |
0.1 |
45 |
56.5 |
P |
4 |
0…..4 |
12 |
0.2 |
33 |
47 |
P |
6 |
0….6 |
12 |
0.2 |
33 |
47 |
P |
10 |
1.....10 |
24 |
0.4 |
27 |
42.5 |
P |
16 |
1…..16 |
24 |
0.4 |
27 |
42.5 |
P |
25 |
2…..25 |
40 |
1 |
33 |
47 |
P |
40 |
4….40 |
40 |
1 |
33 |
47 |
PRESSOSTAT PS...
P version without see-through lid
Data sheet H72252
Instruction H71261
Sensor technology |
bellows |
Sensor material |
bronze,brass |
Protection |
IP65 |
Pressure connection |
G1/4“ female |
Output |
micro switch |
Electrical connection |
terminal screw |
Operating temperature [°C] |
-20...+70 |
Media temperature [°C] |
-40...+150 |
EN 60730-2-6 |
Type 2.B.H. |
Mounting plate see MB31 (chapter Accessories)
Type |
Range P
[bar] |
Max. Overpressure [bar] |
Switching diff. fixed
[bar] |
Diameter Y
[mm] |
Length X
[mm] |
PS |
1.5 |
-0.9...1.5 |
10 |
0.1 |
45 |
56.5 |
PS |
2.5 |
0.2....2.5 |
10 |
0.1 |
45 |
56.5 |
PS |
6 |
0….6 |
12 |
0.2 |
33 |
47 |
PS |
16 |
1…..16 |
24 |
0.4 |
27 |
42.5 |
PS |
40 |
4….40 |
40 |
1 |
27 |
42.5 |