Trafag Pressure Transmitter
CANopen MINIATURE PRESSURE-TRANSMITTER CMP...M
CANopen bus smallest design, for high vibrations & high temperatures, medium accuracy
Data sheet H72614
Instruction H73614
Kind of measurement |
relative pressure |
Sensor technology |
thin film on steel |
Sensor material |
1.4542/630 |
Protection |
IP65 |
Pressure connection |
G1/4“ male |
Pressure peak damping element |
integrated |
Output |
CANopen bus protocol |
Electrical connection |
M12x1 |
Operating temperature [°C] |
-40...+85 |
Media temperature [°C] |
-50...+125 |
Versions with higher accuracy and higher temperature resistance see data sheet
Type |
Range P [bar] |
Max. Overpressure [bar] |
Supply [VDC] |
Accuracy Nlh(BSL)
[% FS typ.] |
CMP |
4.0M |
0…..4.0 |
8 |
8…32 |
+/-0.2 |
CMP |
6.0M |
0…..6.0 |
12 |
8…32 |
+/-0.2 |
CMP |
10.0M |
0….10.0 |
20 |
8…32 |
+/-0.2 |
CMP |
16.0M |
0.....16.0 |
32 |
8…32 |
+/-0.2 |
CMP |
25.0M |
0…..25.0 |
50 |
8…32 |
+/-0.2 |
CMP |
40.0M |
0…..40.0 |
80 |
8…32 |
+/-0.2 |
CMP |
100.0M |
0….100.0 |
200 |
8…32 |
+/-0.2 |
CMP |
250.0M |
0….250.0 |
500 |
8…32 |
+/-0.2 |
CMP |
400.0M |
0….400.0 |
800 |
8…32 |
+/-0.2 |
COPCON Female electrical connector M12x1, 5 poles |