Trafag Ex Instruments
EX-INDUSTAT, EXS EXS...
rugged housing.internal set-point adjustment
Data sheet H72108
Instruction H73172
Set-point adjustment |
internal |
Sensor technology |
capillary tube, remote sensor |
Protection |
IP65 |
Output |
micro switch |
Electrical connection |
terminal screw |
EN 60730-2-9 |
Type 2.B.H. |
Capillary tube length [m] |
2 |
Protection tubes see end of this chapter
Areas with gas explosion hazards EX II 2 G Ex de IIC T6
Areas with dust explosion hazards EX II 2 D Ex tD A21 IP 66 T 80 °C
Type |
Sensor material |
Range T
[°C] |
Switching diff.
fixed
[°C] |
Operating
temperature
[°C] |
Media
Temperature
[°C] |
EXS |
35 |
Cu Ni-plated |
0...35 |
2.5 |
-30...50 |
max.50 |
EXS |
40 |
Cu Ni-plated |
-30...40 |
2.5 |
-30...45 |
max.45 |
EXS |
95 |
Cu Ni-plated |
5....95 |
3.5 |
-30...65 |
max.105 |
EXS |
150 |
Cu Ni-plated |
20...150 |
5.5 |
-30...65 |
max.165 |
EXS |
230 |
1.4435/316L |
20...230 |
8 |
-30...65 |
max.250 |
EXS |
350 |
1.4435/316L |
70...350 |
10 |
-30...65 |
max.380 |