Trafag Mechanical Thermostats
INDUSTAT I...
controller with rugged housing
external set-point adjustment
Data sheet H72110
Instruction H73111
Set-point adjustment |
external |
Sensor technology |
capillary tube, remote sensor |
Protection |
IP65 |
Output |
micro switch |
Electrical connection |
terminal screw |
Operating temperature [°C] |
-30...+70 |
EN 60730-2-9 |
Type 2.B.H. |
Capillary tube length [m] |
2 |
Protection tubes see end of this chapter
Type |
Sensor material |
Range T
[°C] |
Switching diff.
Adjustable
[°C] |
Media
Temperature
[°C] |
I |
35 |
Cu |
0...35 |
0.7...10 |
max.60 |
I |
40 |
Cu |
-30...40 |
0.7...10 |
max.45 |
I |
95 |
Cu |
5....95 |
2...12 |
max.105 |
I |
150 |
Cu |
20...150 |
2.5..16 |
max.165 |
I |
230S |
1.4435/316L |
20...230 |
3...32 |
max.250 |
I |
350S |
1.4435/316L |
70...350 |
4....40 |
max.380 |
INDUSTAT IS...
controller with rugged housing
external set-point adjustment
Data sheet H72110
Instruction H73111
Set-point adjustment |
internal |
Sensor technology |
capillary tube, remote sensor |
Protection |
IP65 |
Output |
micro switch |
Electrical connection |
terminal screw |
Operating temperature [°C] |
-30...+70 |
EN 60730-2-9 |
Type 2.B.H. |
Capillary tube length [m] |
2 |
Protection tubes see end of this chapter
Type |
Sensor material |
Range T
[°C] |
Switching diff.
Adjustable
[°C] |
Media
Temperature
[°C] |
IS |
35 |
Cu |
0...35 |
0.7...10 |
max.60 |
IS |
40 |
Cu |
-30...40 |
0.7...10 |
max.45 |
IS |
95 |
Cu |
5....95 |
2...12 |
max.105 |
IS |
150 |
Cu |
20...150 |
2.5..16 |
max.165 |
IS |
230S |
1.4435/316L |
20...230 |
3...32 |
max.250 |
IS |
350S |
1.4435/316L |
70...350 |
4....40 |
max.380 |
INDUSTRIAL LIMITER WITH REMOTE SENSOR IS_R...
rugged housing
internal set-point adjustment & external reset knob
Data sheet H72138
Instruction H73115
Set-point adjustment |
internal, external restet |
Sensor technology |
capillary tube, remote sensor |
Protection |
IP65 |
Output |
micro switch |
Electrical connection |
terminal screw |
Operating temperature [°C] |
-30...+70 |
EN 60730-2-9 |
Type 2.B.H. |
Capillary tube length [m] |
2 |
Calibrated for increasing temp |
T∕ |
Protection tubes see end of this chapter
Type |
Sensor material |
Range T
[°C] |
Media
Temperature
[°C] |
IS |
95R |
Cu |
5....95 |
max.105 |
IS |
150R |
Cu |
20...150 |
max.165 |
IS |
230SR |
1.4435/316L |
20...230 |
max.250 |
IS |
350SR |
1.4435/316L |
70...350 |
max.380 |