Supply voltage |
14...28 VAC (50/60 Hz)
85...265 VAC (50/60 Hz)
10...30 VDC |
Power consumption |
5 VA
4 W |
Sensor supply |
18 VDC ±15 % / 100 mA |
Display |
LED, 7-segment display |
Number of digits |
6-digits |
Digit height |
7.6 mm |
Function |
Preset counter
Main counter with 2 presets
Totalizer
Hour counter |
Scaling factor |
0.0001...9999.99 |
Count modes |
Adding or subtracting
A-B (difference counting)
A+B total (parallel counting)
Up/Down
A 90° B phase evaluation |
Counting frequency |
3 Hz, 25 Hz, 10 kHz programmable |
Operating modes |
Step preset
Main preset
Parallel alignment
Trailing preset |
Data memory |
>10 years in EEPROM |
Reset |
Button, electric or automatic |
Keylock |
Yes, electric (keylock) |
Outputs relay |
Normally open or closed, programmable |
Output holding time |
0.01...99.99 s |
Interfaces |
RS232
RS422
RS485 |
Standard
DIN EN 61010‑1 |
Protection class II
Overvoltage category II
Pollution degree 2 |
Emitted interference |
DIN EN 61000-6-3 |
Interference immunity |
DIN EN 61000-6-2 |
Programmable
parameters |
Operating modes
Sensor logic
Scaling factor
Count mode
Control inputs |
Approvals |
UL/cUL
CE conform |
Operating temperature |
0...+50 °C |
Storing temperature |
-20...+70 °C |
Relative humidity |
80 % non-condensing |
E-connection |
Plug-in screw terminals
D-SUB-female connector, 9-pins (interface) |
Core cross-section |
1.5 mm² |
Protection DIN EN 60529 |
IP 50 face DIN 0470-1 |
Operation / keypad |
Membrane with softkeys |
Housing type |
Surface mount housing |
Dimensions W x H x L |
70 x 89 x 58 mm |
Installation depth |
58 mm |
Mounting |
DIN rail housing EN 50022 |
Materials |
Housing: GFV Polycarbonat
Rear: PPO
Keypad: Polyester |
Weight approx. |
300 g |