Supply voltage |
24/110 VAC ±10 % (50/60 Hz)
230 VAC +6/-10 % (50/60 Hz)
24 VDC ±10 % |
Ripple residue |
<48 % |
Nominal frequency |
50 / 60 Hz |
Impulse ratio |
1:1 |
Service life |
100 million impulses
Electric reset operations: Approx. 1 million |
Preset |
1 preset |
Output contact |
Change-over contact by micro-switch, one-pole |
Switching voltage |
230 VAC / VDC |
Switching current |
2 A (VAC)
1 A (VDC) |
Switching capacity |
100 VA / 30 W |
Limit switch service life |
1 million switching cycles |
Spark extinguisher |
Recommended for inductive load |
Standard
DIN EN 61010‑1 |
Protection class II
Overvoltage category II
Pollution degree 2 |
Emitted interference |
DIN EN 61000-6-3 |
Interference immunity |
DIN EN 61000-6-2 |
Approval |
CE conform |
Display |
White numbers on black |
Number of digits |
5-digits |
Digit height |
8 mm |
Count mode |
1 impulse = 1 count |
Step-by-step switching |
Subtracting in 2 half steps |
Measuring range |
99 999 |
Reset |
Manual by button to preset |
Operating temperature |
0...+60 °C |
Storing temperature |
-20...+70 °C |
Relative humidity |
80 % non-condensing |
Protection DIN EN 60529 |
IP 41 |
Housing type |
Built-in housing |
E-connection |
Plug-in terminal connector, 10-pins |
Mounting |
Front panel with 4 screws |
Dimensions W x H x L |
144 x 72 x 129 mm |
Cutout dimensions |
113 x 61 mm (+0.5) |
Installation depth |
129 mm |
Weight approx. |
650 g |
Material |
Housing: Hostaform POM, black |